Part Number Hot Search : 
70000 X202C D1835 4511BD SHGM1430 63E6FS SM626HRR LTC1285
Product Description
Full Text Search
 

To Download JQ1A-12V Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 VDE
HIGH ELECTRICAL & MECHANICAL NOISE IMMUNITY RELAY
10 .394
JQ RELAYS
20 .787
FEATURES
* High electrical noise immunity * High switching capacity in a compact package * High sensitivity: 200 mW (1a), 400 mW (1c) * High surge voltage: 8,000 V between contacts and coil * UL, CSA, VDE, TUV, SEMKO approved * Class B coil insulation type available
mm inch
15.6 .614
SPECIFICATIONS
Contact
Arrangement Standard type High capacity type 1 Form A, 1 Form C 100 m Silver alloy 5 A 125 V AC 10 A 125 V AC 2 A 250 V AC 5 A 250 V AC 5 A 30 V DC 5 A 30 V DC 5 A 125 V AC 10 A 125 V AC 2 A 250 V AC 5 A 250 V AC 3 A 30 V AC 5 A 30 V DC 2 A 125 V AC 3 A 125 V AC 1 A 250 V AC 2 A 250 V AC 1 A 30 V DC 1 A 30 V DC
Characteristics
Max. operating speed Initial insulation resistance*1 Initial Between open contacts breakdown voltage*2 Between contacts and coil Surge voltage between contact and coil*3 Operate time*4 (at nominal voltage) Release time*4 (at nominal voltage)(without diode) Temperature rise*5 Functional*6 Shock resistance Destructive*7 Vibration resistance Functional*8 Destructive 20 cpm Min. 1,000 M at 500 V DC 1a: 1,000 Vrms for 1 min. 1c: 750 Vrms for 1 min. 4,000 Vrms for 1 min. 8,000 V Approx. 5 ms Approx. 2 ms Max. 45C Min. 294 m/s2 {30 G} Min. 980 m/s2 {100 G} 98 m/s2 {10 G}, 10 to 55 Hz at double amplitude of 1.6 mm 117.6 m/s2 {12 G}, 10 to 55 Hz at double amplitude of 2.0 mm -40C to +85C -40F to +185F 5 to 85% R.H. Approx. 7 g .25 oz
Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact material
1a
Nominal switching capacity
N.O. 1c N.C.
Rating (resistive)
Max. switching power
1a 625 VA, 150 W 1,250 VA, 150 W N.O. 625 VA, 90 W 1,250 V AC, 150 W 1c N.C. 250 VA, 30 W 500 V AC, 30 W Max. switching voltage 250 V AC, 110 V DC (0.3A) Max. switching current N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A Expected mechanical life 107 (at 180 cpm)(min. operations)
Conditions for operation, Ambient transport and storage*9 temp.*10 (Not freezing and condensHumidity ing at low temperature)
Expected electrical life (min. operations)
Type 1a Switching capacity 5 A 125 V AC 3 A 125 V AC 2 A 250 V AC 5 A 30 V DC 5 A 125 V AC 2 A 250 V AC 3 A 30 V DC 2 A 125 V AC 1 A 250 V AC 1 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 10 A 125 V AC 5 A 250 V AC 5 A 30 V DC 3 A 125 V AC 2 A 250 V AC 1 A 30 V DC No. of operations 5x104 2x105 2x105 105 5x104 2x105 105 2x105 2x105 105 5x104 5x104 105 5x104 5x104 105 2x105 2x105 105
Unit weight Remarks
* *1 *2 *3 *4 *5
Specifications will vary with foreign standards certification ratings. Measurement at same location as "Initial breakdown voltage" section Detection current: 10 mA Wave is standard shock voltage of 1.2 x 50s according to JEC-212-1981 Excluding contact bounce time Measured conditions
Resistive, nominal voltage applied to the coil. Contact carrying current: 5 A, at 70C 158F Resistive, nominal voltage applied to the coil. Contact carrying current: 10 A, at 70C 158F
Standard type 1c
N.O.
Standard type High capacity type
N.C.
*6 *7 *8 *9 *10
1a High capacity type 1c N.C.
N.O.
Half-wave pulse of sine wave: 11ms; detection time: 10s Half-wave pulse of sine wave: 6ms Detection time: 10s Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 24). When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with 20C 68F as a reference) and use a coil impressed voltage that is within the maximum allowable voltage range.
Coil (at 20C 68F)
Nominal operating power 1a: 200 mW 1c: 400 mW
71
JQ
TYPICAL APPLICATIONS
* Air conditioners * Refrigerators * Microwave ovens * Heaters
ORDERING INFORMATION
Ex. Contact arrangement 1a: 1 Form A 1: 1 Form C JQ 1a P B 12 V
Contact capacity Nil: Standard P: High capacity
Coil insulation class Nil: Class E coil insulation B: Class B coil insulation
Coil voltage (DC) 5, 6, 9, 12, 18, 24, 48* V
UL/CSA, VDE, SEMKO approved type is standard. * Available only for 1 Form C type
TYPES AND COIL DATA at 20C 68F
Part No. JQ1a-5V JQ1a-6V JQ1a-9V JQ1A-12V JQ1a-18V JQ1a-24V JQ1aP-5V JQ1aP-6V JQ1aP-9V JQ1aP-12V JQ1aP-18V JQ1aP-24V JQ1-5V JQ1-6V JQ1-9V JQ1-12V JQ1-18V JQ1-24V JQ1-48V JQ1P-5V JQ1P-6V JQ1P-9V JQ1P-12V JQ1P-18V JQ1P-24V JQ1P-48V Nominal voltage, V DC 5 6 9 12 18 24 5 6 9 12 18 24 5 6 9 12 18 24 48 5 6 9 12 18 24 48 Pick-up voltage, V DC (min.) 3.75 4.5 6.75 9 13.5 18 4 4.8 7.2 9.6 14.4 19.2 3.75 4.5 6.75 9 13.5 18 36 4 4.8 7.2 9.6 14.4 19.2 38.4 Drop-out voltage, V DC (min.) 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 0.25 0.3 0.45 0.6 0.9 1.2 2.4 0.25 0.3 0.45 0.6 0.9 1.2 2.4 Nominal operating current, mA 40 33.3 22.2 16.7 11.1 8.3 40 33.3 22.2 16.7 11.1 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 80 66.7 44.4 33.3 22.2 16.7 8.3 Nominal operating power, mW Coil resistance, (10%) 125 180 405 720 1,620 2,880 125 180 405 720 1,620 2,880 62.5 90 202.5 360 810 1,440 5,760 62.5 90 202.5 360 810 1,440 5,760 Max. allowable voltage, V DC
Standard type
200
180% of nominal voltage (at 20C 68F)
1 Form A
High capacity type
200
130% of nominal voltage (at 85C 185F)
Standard type
400
150% of nominal voltage (at 20C 68F)
1 Form C
High capacity type
400
110% of nominal voltage (at 85C 185F)
72
JQ
DIMENSIONS
1 Form A
10 .394 20 .787
mm inch
1 Form A
Schematic (Bottom view) 1 Form C
COM N.O. Coil N.C. COM N.O.
15.6 .614 0.4 .016 7.62 .300 4.2 .165 0.5 dia. .020 dia. 10.16 .400 0.3 .012 7.62 .300 0.3 .012 7.62 .300 0.8 .031
Coil
1 Form C
10 .394 20 .787
PC board pattern (Copper-side view) 1 Form A 1FormC
10.16 .400 7.62 .300 4-1.3 dia. 4-.051 dia. 10.16 .400 7.62 .300 5-1.3 dia. 5-.051 dia.
15.6 .614 0.4 .016 7.62 .300 4.2 .165 0.5 dia. .020 dia. 10.16 .400 0.3 .012 5.08 .200 2.54 .100 0.3 .012 0.3 .012 7.62 .300 0.8 .031
7.62 .300
7.62 .300
Tolerance: 0.1 .004
Dimension : Max. 1mm .039 inch 1 to 5mm .039 to .118 inch Min. 5mm .118 inch
General tolerance 0.2 .008 0.3 .012 0.4 .016
REFERENCE DATA
Max. switching capacity (1 Form A type)
100 Contact current, A
Max. switching capacity (1 Form C type)
100 AC resistive load (High capacity type) N.O. side AC resistive load (Standard type) N.O. side 10 5 3 2 AC resistive load 1 (High capacity type) N.C. side AC resistive load (Standard type) N.C. side
Contact current, A
AC resistive load (High capacity type) 10 5
1 AC resistive load (Standard type)
10
100 277 Contact voltage, V
1,000
10
100 277 Contact voltage, V
1,000
Standard type 1-(1). Operate & release time (1 Form A type)
Tested sample: JQ1A-12V, 25 pcs.
1-(2). Operate & release time (1 Form C type)
Tested sample: JQ1-24V, 25 pcs.
2. Life curve
Ambient temperature: room temperature
100 Operate & release time, ms Operate & release time, ms
8
8 Life, x104
125V AC resistive load
6 Operate time 4 Max. Max. Min. Min.
6 Operate time 4 Max. Max. Min. Min. Release time 0 80 100 120 150
10 250V AC resistive load
2 Release time 0
2
1
80
100
120
150
0
1
2
3
4
5
Coil applied voltage, %V
Coil applied voltage, %V
Contact current, A
73
JQ
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 3 A, 5 A Measured portion: Inside the coil
50 Temperature rise, C Temperature rise, C
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 3 A, 5 A Measured portion: Inside the coil
70 60 5 A at 70C 50 3 A at 70C 40 5 A at 85C 30 3 A at 85C 20 10
40
5 A at 70C 5 A at 85C
30
20 3 A at 70C 3 A at 85C 10
0
100 110 120 130 140 150 160 170 180 190 Coil applied voltage, %V
0
100
110
120
130
140
150
160
Coil applied voltage, %V
4-(1). Ambient temperature characteristics (1 Form A type)
Tested sample: JQ1a-24V Contact carrying current: 3 A, 5 A
400 Coil applied voltage, %V
4-(2). Ambient temperature characteristics (1 Form C type)
Tested sample: JQ1-24V Contact carrying current: 3 A, 5 A
400 Coil applied voltage, %V
300 1 2 200 3 5 100 7 0 20 30 40 50 60 70 80 90 6 4
300 1 200 5 100 6 0 20 30 40 7 50 60 70 80 90 2 3 4
Ambient temperature, C
Ambient temperature, C
1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 3 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 5 A) 3 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 3 A) 4 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 5 A) 5 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) 6 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 3 A) 7 Pick-up voltage
High capacity type
1-(1). Operate & release time (1 Form A type)
Tested sample: JQ1aP-12V, 25 pcs.
Operate & release time, ms
1-(2). Operate & release time (1 Form C type)
Tested sample: JQ1P-12V, 25 pcs.
Operate & release time, ms
2. Life curve
Ambient temperature: room temperature
100
8
8 Life, x104
6
Operate time
6 Operate time 4 Max. Max. Min. Min.
125V AC resistive load 10
4
2
Max. Min. Max. Min. Release time
2 Release time
250V AC resistive load
0
80
100
120
150
0
80
100
120
150
1
0
2
4
6
8
10
Coil applied voltage, %V
Coil applied voltage, %V
Contact current, A
3-(1). Coil temperature rise (1 Form A type)
Contact carrying current: 5 A, 10 A Measured portion: Inside the coil
70 Temperature rise, C
3-(2). Coil temperature rise (1 Form C type)
Contact carrying current: 5 A, 10 A Measured portion: Inside the coil
70 10 A at 85C Temperature rise, C 60 10 A at 70C 50 40 30 20 10 5 A at 70C 5 A at 85C
60 10 A at 85C 50 10 A at 70C 40 30 5 A at 85C 20 10 0 100 120 140 160 180 5 A at 70C
0
100
110
120
130
140
150
160
Coil applied voltage, %V
Coil applied voltage, %V
74
JQ
4-(1). Ambient temperature characteristics (1 Form A type)
Tested sample: JQ1aP-24V Contact carrying current: 5 A, 10 A
400 Coil applied voltage, %V Coil applied voltage, %V 1 300 2
4-(2). Ambient temperature characteristics (1 Form C type)
Tested sample: JQ1P-24V Contact carrying current: 5 A, 10 A
400
300 1 2 200 5 100 3 4
200 5 100 6 0 20 30
3 4
7 40 50 60 70 80 90 0 20
6 30 40
7 50 60 70 80 90
Ambient temperature, C
Ambient temperature, C
1 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 5 A) 2 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 130C 266F) (Carrying current: 10 A) 3 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 5 A) 4 Allowable ambient temperature against % coil voltage (max. inside the coil temperature set as 115C 239F) (Carrying current: 10 A) 5 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 10 A) 6 Pick-up voltage with a hot-start condition of 100%V on the coil (Carrying current: 5 A) 7 Pick-up voltage
For Cautions for Use, see Relay Technical Information (Page 11 to 39).
12/27/2002
All Rights Reserved, (c) Copyright Matsushita Electric Works, Ltd. 75 Go To Online Catalog


▲Up To Search▲   

 
Price & Availability of JQ1A-12V

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X